1,878 research outputs found

    Scintillator manufacture at Fermilab

    Full text link
    A decade of research into plastic scintillation materials at Fermilab is reviewed. Early work with plastic optical fiber fabrication is revisited and recent experiments with large-scale commercial methods for production of bulk scintillator are discussed. Costs for various forms of scintillator are examined and new development goals including cost reduction methods and quality improvement techniques are suggested

    A real-space, rela-time method for the dielectric function

    Full text link
    We present an algorithm to calculate the linear response of periodic systems in the time-dependent density functional thoery, using a real-space representation of the electron wave functions and calculating the dynamics in real time. The real-space formulation increases the efficiency for calculating the interaction, and the real-time treatment decreases storage requirements and the allows the entire frequency-dependent response to be calculated at once. We give as examples the dielectric functions of a simple metal, lithium, and an elemental insulator, diamond.Comment: 17 pages, Latex, 5 figure

    The Interactions of Surface Damage on RF Cavity Operation

    Get PDF
    Studies of low frequency RF systems for muon cooling has led to a variety of new techniques for looking at dark currents, a new model of breakdown, and, ultimately, a model of RF cavity operation based on surface damage. We find that cavity behavior is strongly influenced by the spectrum of enhancement factors on field emission sites.Three different spectra are involved: one defining the initial state of the cavity, the second determined by the breakdown events, and the third defining the equilibrium produced as a cavity operates at its maximum field. We have been able to measure these functions and use them to derive a wide variety of cavity parameters: conditioning behavior, material, pulse length, temperature, vacuum, magnetic field, pressure, gas dependence. In addition we can calculate the dependence of breakdown rate on surface field and pulse length. This work correlates with data from Atom Probe Tomography. We will describe this model and new experimental data

    PHYSICAL PERFORMANCE AND BODY COMPOSITION IN MAINTENANCE HEMODIALYSIS (MHD) PATIENTS

    Get PDF
    BackgroundMHD patients (pts) often display protein-energy wasting, sarcopenia & diminished physical performance. This study was undertaken to assess the relationship between body composition & physical performance in MHD pts.MethodsBody composition, assessed by dual energy x-ray absorptiometry and body mass index (BMI), were compared to 3 measures of physical performance: 6-minute walking distance (6-MW), sit-to-stand testing and stair climb. 52 clinically stable MHD pts (≥6 mo) and 21 matched normal controls were examined in this ongoing study.ResultsPts were 53±13SD yrs, 33% female; 38% diabetic; dialysis vintage was 62±52 months. Normals were 52 years and 43% female. MHD pts had higher % body fat than Normals. 6-MW and sit to stand cycles were much lower in MHD men and women than in Normal men and women. 6MW in MHD and Normals were 445 vs 630 meters, respectively (p<.001). In men but not women, time to climb 22 stairs was greater in MHD pts then in Normals (p=.03). Unadjusted analyses in MHD indicated that 6-MW distance correlated negatively with lean body mass index (LBMI, kg of LBM/m2; r=-0.37; p<0.01) and % body fat (r=-0.33; p= 0.02); stair climb time correlated negatively with lean leg mass (r=-0.32, p=0.03) and total leg mass (r=-0.29, p=0.045).). Sit-to-stand did not correlate with any body composition measure. 6-MW adjusted for age and gender correlated negatively with LBMI (r=-0.29; p=0.04).There were no associations between BMI (range, 19.8-44.2 kg/m2) and physical performance.ConclusionsThese findings indicate that adult MHD pts had a higher % body fat. Measures of physical performance were markedly reduced in MHD pts as compared to Normals. Physical performance in MHD, measured especially by 6-MW, correlated negatively with some measures of body composition, particularly with LBMI

    Valence band photoemission from the GaN(0001) surface

    Full text link
    A detailed investigation by one-step photoemission calculations of the GaN(0001)-(1x1) surface in comparison with recent experiments is presented in order to clarify its structural properties and electronic structure. The discussion of normal and off-normal spectra reveals through the identified surface states clear fingerprints for the applicability of a surface model proposed by Smith et al. Especially the predicted metallic bonds are confirmed. In the context of direct transitions the calculated spectra allow to determine the valence band width and to argue in favor of one of two theoretical bulk band structures. Furthermore a commonly used experimental method to fix the valence band maximum is critically tested.Comment: 8 pages, 11 eps files, submitted to PR

    Cosmic ray tests of the D0 preshower detector

    Full text link
    The D0 preshower detector consists of scintillator strips with embedded wavelength-shifting fibers, and a readout using Visible Light Photon Counters. The response to minimum ionizing particles has been tested with cosmic ray muons. We report results on the gain calibration and light-yield distributions. The spatial resolution is investigated taking into account the light sharing between strips, the effects of multiple scattering and various systematic uncertainties. The detection efficiency and noise contamination are also investigated.Comment: 27 pages, 24 figures, submitted to NIM

    The design, construction and performance of the MICE scintillating fibre trackers

    Get PDF
    This is the Pre-print version of the Article. The official published version can be accessed from the link below - Copyright @ 2011 ElsevierCharged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.This work was supported by the Science and Technology Facilities Council under grant numbers PP/E003214/1, PP/E000479/1, PP/E000509/1, PP/E000444/1, and through SLAs with STFC-supported laboratories. This work was also supportedby the Fermi National Accelerator Laboratory, which is operated by the Fermi Research Alliance, under contract No. DE-AC02-76CH03000 with the U.S. Department of Energy, and by the U.S. National Science Foundation under grants PHY-0301737,PHY-0521313, PHY-0758173 and PHY-0630052. The authors also acknowledge the support of the World Premier International Research Center Initiative (WPI Initiative), MEXT, Japan
    corecore